Assessment Year | 1990 |
---|---|
Principal Product | PAPER BAGS |
NAICS |
n/a
|
SIC | 2674: Uncoated Paper and Multiwall Bags |
Sales Range | $10 M to 50M |
# of Employees | 44 |
Plant Area |
n/a
|
Annual Production | 600,000,000
pieces
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,159 | 1,376,026 |
kWh
|
$0.050 |
Natural Gas | $13,617 | 2,573 |
MMBtu
|
$5.29 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,493 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,050 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7111: Reduce illumination to minimum necessary levels | $5,596 | $312 |
$5,596
95,252
kWh
|
- | |
02 | 2.4133: Use most efficient type of electric motors | $148 | $50 |
$148
2,931
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,902 | $1,000 |
$1,902
38,101
kWh
|
- | |
04 | 2.3212: Optimize plant power factor | $473 | $1,200 |
$473
-
kWh
|
- | |
05 | 2.7492: Use proper thickness of insulation on building envelope | $7,374 | $31,672 | - |
$7,374
-
MMBtu
|
|
TOTAL RECOMMENDED | $15,493 | $34,234 |
$8,119
136,284
kWh
|
$7,374
-
MMBtu
|
||
TOTAL IMPLEMENTED | $2,050 | $1,050 |
$2,050
41,032
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs