| Assessment Year | 1989 |
|---|---|
| Principal Product | LUMBER |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 70 |
| Plant Area |
n/a
|
| Annual Production | 52,000
thousand feet
|
| Production Hrs. Annual | 8,568
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $339,153 | 7,228,019 |
kWh
|
$0.047 |
| Wood | $64,260 | 154,224 |
MMBtu
|
$0.42 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $25,218 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $22,403 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Wood Savings |
|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $1,915 | $500 | - |
$1,915
-
MMBtu
|
|
| 02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $17,682 | $5,000 |
$17,682
376,319
kWh
|
- | |
| 03 | 2.4133: Use most efficient type of electric motors | $106 | $181 |
$106
2,345
kWh
|
- | |
| 04 | 2.3212: Optimize plant power factor | $900 | $2,250 |
$900
-
kWh
|
- | |
| 05 | 2.5123: Reduce fluid flow rates | $4,615 | $12,560 |
$4,615
138,628
kWh
|
- | |
| TOTAL RECOMMENDED | $25,218 | $20,491 |
$23,303
517,292
kWh
|
$1,915
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $22,403 | $17,741 |
$22,403
517,292
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs