Assessment Year | 1989 |
---|---|
Principal Product | CLADWOOD |
NAICS |
n/a
|
SIC | 2493: Reconstituted Wood Products |
Sales Range | $10 M to 50M |
# of Employees | 43 |
Plant Area |
n/a
|
Annual Production | 241,235
ton
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $253,856 | 6,031,067 |
kWh
|
$0.042 |
Natural Gas | $234,481 | 107,124 |
MMBtu
|
$2.19 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,876 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,770 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2511: Insulate bare equipment | $1,145 | $443 | - |
$1,145
-
MMBtu
|
|
02 | 2.2511: Insulate bare equipment | $1,169 | $553 | - |
$1,169
-
MMBtu
|
|
03 | 2.1213: Direct warmest air to combustion intake | $1,773 | $1,200 | - |
$1,773
-
MMBtu
|
|
04 | 2.4133: Use most efficient type of electric motors | $439 | $425 |
$439
10,551
kWh
|
- | |
05 | 2.2437: Recover waste heat from equipment | $4,067 | $947 |
$810
19,343
kWh
|
$3,257
-
MMBtu
|
|
06 | 2.3212: Optimize plant power factor | $3,950 | $8,400 |
$3,950
-
kWh
|
- | |
07 | 2.1213: Direct warmest air to combustion intake | $333 | $1,000 | - |
$333
-
MMBtu
|
|
TOTAL RECOMMENDED | $12,876 | $12,968 |
$5,199
29,894
kWh
|
$7,677
-
MMBtu
|
||
TOTAL IMPLEMENTED | $10,770 | $10,768 |
$5,199
29,894
kWh
|
$5,571
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |