Assessment Year | 1988 |
---|---|
Principal Product | FABRICATED LAMB |
NAICS |
n/a
|
SIC | 2011: Meat Packing Plants |
Sales Range | $10 M to 50M |
# of Employees | 55 |
Plant Area |
n/a
|
Annual Production | 12,200,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Washington |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $58,992 | 1,653,576 |
kWh
|
$0.036 |
LPG | $41,930 | 11,799 |
MMBtu
|
$3.55 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $13,188 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $5,758 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2444: Use hot process fluids to preheat incoming process fluids | $1,601 | $320 | - |
$1,601
-
MMBtu
|
- | |
02 | 2.1243: Use heat from boiler blowdown to preheat boiler feed water | $614 | $513 | - |
$614
-
MMBtu
|
- | |
03 | 2.4133: Use most efficient type of electric motors | $61 | $64 |
$61
1,758
kWh
|
- | - | |
04 | 2.2444: Use hot process fluids to preheat incoming process fluids | $3,612 | $5,792 | - |
$3,612
-
MMBtu
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,758 | $8,921 |
$2,691
74,736
kWh
|
- | $3,067 | |
06 | 2.2414: Use waste heat from hot flue gases to preheat | $1,542 | $3,258 | - |
$1,542
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $13,188 | $18,868 |
$2,752
76,494
kWh
|
$7,369
-
MMBtu
|
$3,067 | ||
TOTAL IMPLEMENTED | $5,758 | $8,921 |
$2,691
74,736
kWh
|
- | $3,067 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | LPG Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs