| Assessment Year | 1988 |
|---|---|
| Principal Product | LUMBER & WOOD CHIPS |
| NAICS |
n/a
|
| SIC | 2421: Sawmills and Planing Mills, General |
| Sales Range | $10 M to 50M |
| # of Employees | 90 |
| Plant Area |
n/a
|
| Annual Production | 70,000
thousand feet
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $223,114 | 4,264,947 |
kWh
|
$0.052 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,767 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,968 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $6,528 | $3,000 |
$6,528
125,440
kWh
|
|
| 02 | 2.4133: Use most efficient type of electric motors | $373 | $350 |
$373
7,034
kWh
|
|
| 03 | 2.7492: Use proper thickness of insulation on building envelope | $1,799 | $3,021 |
$1,799
34,584
kWh
|
|
| 04 | 2.3212: Optimize plant power factor | $3,067 | $7,800 |
$3,067
-
kWh
|
|
| TOTAL RECOMMENDED | $11,767 | $14,171 |
$11,767
167,058
kWh
|
||
| TOTAL IMPLEMENTED | $9,968 | $11,150 |
$9,968
132,474
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs