| Assessment Year | 1988 |
|---|---|
| Principal Product | VARIOUS DAIRY PRODUCTS |
| NAICS |
n/a
|
| SIC | 2026: Fluid Milk |
| Sales Range | $10 M to 50M |
| # of Employees | 86 |
| Plant Area |
n/a
|
| Annual Production | 33,000,000
lb
|
| Production Hrs. Annual | 2,860
hrs
|
| Location (State) | Oregon |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $60,587 | 1,109,027 |
kWh
|
$0.055 |
| Natural Gas | $31,335 | 7,110 |
MMBtu
|
$4.41 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $11,189 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,244 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $821 | - |
$821
14,947
kWh
|
- | |
| 02 | 2.2621: Modify refrigeration system to operate at a lower pressure | $2,315 | - |
$2,315
42,204
kWh
|
- | |
| 03 | 2.1233: Analyze flue gas for proper air/fuel ratio | $536 | $300 | - |
$536
-
MMBtu
|
|
| 04 | 2.4133: Use most efficient type of electric motors | $146 | $109 |
$146
2,638
kWh
|
- | |
| 05 | 2.2449: Recover heat from exhausted steam, hot air or hot water | $6,703 | $6,353 | - |
$6,703
-
MMBtu
|
|
| 06 | 2.2414: Use waste heat from hot flue gases to preheat | $630 | $1,445 | - |
$630
-
MMBtu
|
|
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $38 | - |
$38
586
kWh
|
- | |
| TOTAL RECOMMENDED | $11,189 | $8,207 |
$3,320
60,375
kWh
|
$7,869
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $8,244 | $6,762 |
$1,005
18,171
kWh
|
$7,239
-
MMBtu
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs