Assessment Year | 1988 |
---|---|
Principal Product | PUREE CONCENTRATES |
NAICS |
n/a
|
SIC | 2033: Canned Fruits, Vegetables, Preserves, Jams, and Jellies |
Sales Range | $10 M to 50M |
# of Employees | 120 |
Plant Area |
n/a
|
Annual Production | 14,000,000
lb
|
Production Hrs. Annual | 0
hrs
|
Location (State) | Oregon |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $114,769 | 2,016,706 |
kWh
|
$0.057 |
Natural Gas | $217,147 | 53,845 |
MMBtu
|
$4.03 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,057 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $13,311 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.2163: Use minimum steam operating pressure | $326 | - | - |
$326
-
MMBtu
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $818 | - |
$818
14,361
kWh
|
- | - | |
03 | 2.2621: Modify refrigeration system to operate at a lower pressure | $2,710 | - |
$2,710
47,479
kWh
|
- | - | |
04 | 2.2621: Modify refrigeration system to operate at a lower pressure | $6,291 | - |
$6,291
110,492
kWh
|
- | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $3,466 | $300 | - |
$3,466
-
MMBtu
|
- | |
06 | 2.2122: Install / repair insulation on condensate lines | $150 | $76 | - |
$150
-
MMBtu
|
- | |
07 | 3.4115: Recover and reuse cooling water | $502 | $320 | - | - | $502 | |
08 | 2.4133: Use most efficient type of electric motors | $276 | $298 |
$276
4,982
kWh
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $518 | $997 |
$582
10,258
kWh
|
- | $(-64.0) | |
TOTAL RECOMMENDED | $15,057 | $1,991 |
$10,677
187,572
kWh
|
$3,942
-
MMBtu
|
$438 | ||
TOTAL IMPLEMENTED | $13,311 | $1,297 |
$9,583
168,229
kWh
|
$3,792
-
MMBtu
|
$(-64.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs