Assessment Year 1998
Principal Product Ground limestone
NAICS
n/a
SIC 3295: Minerals and Earths, Ground or Otherwise Treated
Sales Range $10
M
to 50
M
# of Employees 49
Plant Area
n/a
Annual Production 275,789
ton
Production Hrs. Annual 8,544
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $702,586 16,172,040
kWh
Electricity Demand $106,272 35,424
kW-mo/yr
Electricity Fees $1,916 -
Natural Gas $2,304 429
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $24,730 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,010

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
01 4.611: Begin a practice of predictive / preventative maintenance $10,500 $4,200 $3,100
68,875
kWh
- - $7,400 -
02 3.5315: Lease / purchase baler; sell cardboard to recycler $4,170 $7,500 - - $4,170
-
lb
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $2,450 $4,530 $2,450
55,100
kWh
- - - -
04 2.4133: Use most efficient type of electric motors $2,010 $3,750 $1,840
41,325
kWh
$170
-
kW-mo/yr
- - -
05 2.4314: Use synthetic lubricant $1,860 - $1,710
35,170
kWh
$150
-
kW-mo/yr
- - -
06 2.7124: Make a practice of turning off lights when not needed $1,470 - $1,470
33,118
kWh
- - - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,450 $1,025 $1,370
19,930
kWh
$80
-
kW-mo/yr
- - -
08 2.7124: Make a practice of turning off lights when not needed $430 - $430
9,672
kWh
- - - -
09 2.8121: Apply for tax-free status for energy purchases $215 $320 - - - - $215
10 2.8121: Apply for tax-free status for energy purchases $175 $320 - - - - $175
TOTAL RECOMMENDED $24,730 $21,645 $12,370
263,190
kWh
$400
-
kW-mo/yr
$4,170
-
lb
$7,400 $390
TOTAL IMPLEMENTED $21,010 $21,005 $9,190
194,902
kWh
$250
-
kW-mo/yr
$4,170
-
lb
$7,400 -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs