| Assessment Year | 2026 |
|---|---|
| Principal Product | Casino Recreation |
| NAICS | 713210: Casinos (except Casino Hotels) |
| SIC | 7999: Amusement and Recreation Services, Not Elsewhere Classified |
| Sales Range | $5 M to 10M |
| # of Employees | 55 |
| Plant Area |
10,000
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 6,048
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $70,561 | 1,051,546 |
kWh
|
$0.067 | |
| Electricity Demand | $22,033 | 1,760 |
kW-mo/yr
|
$12.52 | |
| Natural Gas | $1,654 | 203 |
MMBtu
|
$8.15 | |
| Waste Disposal Costs | |||||
| Water Usage | $2,600 | 317 |
Tgal
|
$8.20 | |
| Water Disposal | $1,814 | 317 |
Tgal
|
$5.72 | |
| TOTAL YEARLY COSTS | $98,662 | ||||
| RECOMMENDED SAVINGS* | $10,999 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,017 | $2,818 |
$742
11,080
kWh
|
$275
-
kW-mo/yr
|
|
| 02 | 2.9114: Use solar heat to make electricty | $6,546 | $80,028 |
$6,546
97,554
kWh
|
- | |
| 03 | 2.7211: Clean and maintain refrigerant condensers and towers | $2,625 | $1,851 |
$2,625
39,119
kWh
|
- | |
| 04 | 2.6211: Conserve energy by efficient use of vending machines | $811 | $474 |
$811
12,089
kWh
|
- | |
| TOTAL RECOMMENDED | $10,999 | $85,171 |
$10,724
159,842
kWh
|
$275
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs