| Assessment Year | 2026 |
|---|---|
| Principal Product | Processed frozen poultry |
| NAICS | 311615: Poultry Processing |
| SIC | 2015: Poultry Slaughtering and Processing |
| Sales Range | $10 M to 50M |
| # of Employees | 470 |
| Plant Area |
220,000
ft2
|
| Annual Production | 216,000,000
lb
|
| Production Hrs. Annual | 7,200
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $3,504,790 | 53,067,600 |
kWh
|
$0.066 | |
| Electricity Demand | $584,083 | 93,323 |
kW-mo/yr
|
$6.26 | |
| Natural Gas | $791,826 | 207,964 |
MMBtu
|
$3.81 | |
| Waste Disposal Costs | |||||
| Water Usage | $399,975 | 143,011 |
Tgal
|
$2.80 | |
| Water Disposal | $641,326 | 143,011 |
Tgal
|
$4.48 | |
| TOTAL YEARLY COSTS | $5,922,000 | ||||
| RECOMMENDED SAVINGS* | $109,542 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $80,220 | $823,680 |
$80,220
1,215,460
kWh
|
- | |
| 02 | 2.7232: Replace existing hvac unit with high efficiency model | $2,714 | $5,280 |
$2,714
41,120
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $26,608 | $15,039 |
$22,977
348,135
kWh
|
$3,631
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $109,542 | $843,999 |
$105,911
1,604,715
kWh
|
$3,631
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs