| Assessment Year | 2026 |
|---|---|
| Principal Product | natural gas burners |
| NAICS | 333994: Industrial Process Furnace and Oven Manufacturing |
| SIC | 3433: Heating Equipment, Except Electric and Warm Air Furnaces |
| Sales Range | $10 M to 50M |
| # of Employees | 166 |
| Plant Area |
91,588
ft2
|
| Annual Production | 792,544
lb
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Kansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $66,959 | 910,478 |
kWh
|
$0.074 | |
| Electricity Demand | $67,126 | 3,676 |
kW-mo/yr
|
$18.26 | |
| Natural Gas | $56,310 | 8,736 |
MMBtu
|
$6.45 | |
| Waste Disposal Costs | |||||
| Water Usage | $11,070 | 749 |
Tgal
|
$14.78 | |
| Water Disposal | $4,577 | 587 |
Tgal
|
$7.80 | |
| TOTAL YEARLY COSTS | $206,042 | ||||
| RECOMMENDED SAVINGS* | $50,335 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.7245: Use direct air supply to exhaust hoods | $1,659 | $3,947 | - | - |
$1,659
-
MMBtu
|
|
| 02 | 4.112: Replace old machine with new automatic multi-station tool | $29,325 | $395,500 |
$9,568
159,474
kWh
|
$19,757
-
kW-mo/yr
|
- | |
| 03 | 2.7135: Install occupancy sensors | $1,749 | $6,954 |
$1,749
29,142
kWh
|
- | - | |
| 04 | 2.9114: Use solar heat to make electricty | $17,602 | $218,400 |
$17,602
293,360
kWh
|
- | - | |
| TOTAL RECOMMENDED | $50,335 | $624,801 |
$28,919
481,976
kWh
|
$19,757
-
kW-mo/yr
|
$1,659
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs