| Assessment Year | 2026 |
|---|---|
| Principal Product | semiconductor manufacturing chemicals |
| NAICS | 334413: Semiconductor and Related Device Manufacturing |
| SIC | 3674: Semiconductors and Related Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 25 |
| Plant Area |
55,000
ft2
|
| Annual Production | 77
ton
|
| Production Hrs. Annual | 6,240
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $134,248 | 2,004,900 |
kWh
|
$0.067 | |
| Electricity Demand | $67,754 | 5,034 |
kW-mo/yr
|
$13.46 | |
| Natural Gas | $38,947 | 6,557 |
MMBtu
|
$5.94 | |
| Waste Disposal Costs | |||||
| Water Usage | $1,752 | 330 |
Tgal
|
$5.31 | |
| Water Disposal | $4,415 | 330 |
Tgal
|
$13.38 | |
| TOTAL YEARLY COSTS | $247,116 | ||||
| RECOMMENDED SAVINGS* | $79,850 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $21,807 | $205,920 |
$21,807
325,476
kWh
|
- | - | - | |
| 02 | 2.7135: Install occupancy sensors | $3,857 | $1,610 |
$3,857
57,567
kWh
|
- | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,304 | $2,574 |
$1,304
19,460
kWh
|
- | - | - | |
| 04 | 2.3212: Optimize plant power factor | $953 | $5,076 | - | - | - | $953 | |
| 05 | 2.2622: Replace existing chiller with high efficiency model | $37,309 | $136,434 |
$17,281
257,920
kWh
|
$20,028
-
kW-mo/yr
|
- | - | |
| 06 | 2.7211: Clean and maintain refrigerant condensers and towers | $1,931 | $3,816 |
$1,931
28,828
kWh
|
- | - | - | |
| 07 | 2.7226: Use computer programs to optimize hvac performance | $6,219 | $55,000 |
$6,219
92,821
kWh
|
- | - | - | |
| 08 | 2.7261: Install timers and/or thermostats | $4,307 | $3,800 | - | - |
$4,307
-
MMBtu
|
- | |
| 09 | 2.6211: Conserve energy by efficient use of vending machines | $377 | $450 |
$377
5,641
kWh
|
- | - | - | |
| 10 | 2.7492: Use proper thickness of insulation on building envelope | $1,786 | $45,790 |
$782
11,665
kWh
|
- |
$1,004
-
MMBtu
|
- | |
| TOTAL RECOMMENDED | $79,850 | $460,470 |
$53,558
799,378
kWh
|
$20,028
-
kW-mo/yr
|
$5,311
-
MMBtu
|
$953 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs