| Assessment Year | 2026 |
|---|---|
| Principal Product | Anti-microbial enzymes |
| NAICS | 541380: Testing Laboratories |
| SIC | 8734: Testing Laboratories |
| Sales Range | $5 M to 10M |
| # of Employees | 22 |
| Plant Area |
22,500
ft2
|
| Annual Production | 17,537
lb
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $66,344 | 568,080 |
kWh
|
$0.12 | |
| Natural Gas | $1,916 | 254 |
MMBtu
|
$7.54 | |
| Waste Disposal Costs | |||||
| Water Usage | $8,194 | 3,993 |
Tgal
|
$2.05 | |
| Water Disposal | $23,748 | 5,472 |
Tgal
|
$4.34 | |
| TOTAL YEARLY COSTS | $100,202 | ||||
| RECOMMENDED SAVINGS* | $45,629 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.9114: Use solar heat to make electricty | $10,845 | $62,586 |
$10,845
92,694
kWh
|
|
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,052 | $12,414 |
$3,052
26,082
kWh
|
|
| 03 | 2.7135: Install occupancy sensors | $884 | $2,870 |
$884
7,557
kWh
|
|
| 04 | 2.7232: Replace existing hvac unit with high efficiency model | $3,376 | $5,665 |
$3,376
28,853
kWh
|
|
| 05 | 2.7211: Clean and maintain refrigerant condensers and towers | $1,973 | $3,370 |
$1,973
16,863
kWh
|
|
| 06 | 2.7226: Use computer programs to optimize hvac performance | $25,417 | $42,525 |
$25,417
217,237
kWh
|
|
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $82 | - |
$82
698
kWh
|
|
| TOTAL RECOMMENDED | $45,629 | $129,430 |
$45,629
389,984
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs