Assessment Year | 2025 |
---|---|
Principal Product | Hydraulic aircraft components |
NAICS | 332912: Fluid Power Valve and Hose Fitting Manufacturing |
SIC | 3728: Aircraft Parts and Auxiliary Equipment, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
85,000
ft2
|
Annual Production | 3,000
units
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $289,494 | 2,851,800 |
kWh
|
$0.10 |
Natural Gas | $64,402 | 16,151 |
MMBtu
|
$3.99 |
TOTAL YEARLY COSTS | $353,896 | |||
RECOMMENDED SAVINGS* | $94,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,824 | $21,492 |
$4,824
47,297
kWh
|
- | |
02 | 2.7211: Clean and maintain refrigerant condensers and towers | $22,291 | $11,690 |
$22,291
218,544
kWh
|
- | |
03 | 2.7226: Use computer programs to optimize hvac performance | $38,968 | $113,400 |
$38,968
382,040
kWh
|
- | |
04 | 2.6211: Conserve energy by efficient use of vending machines | $715 | $560 |
$715
7,008
kWh
|
- | |
05 | 2.3212: Optimize plant power factor | $2,728 | $10,239 | - | $2,728 | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $25,121 | $19,503 |
$25,121
246,282
kWh
|
- | |
TOTAL RECOMMENDED | $94,647 | $176,884 |
$91,919
901,171
kWh
|
$2,728 | ||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs