ITAC Assessment: OK1137
ITAC logo
ITAC Assessment: OK1137
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product welded and machined enclosures
NAICS 332322: Sheet Metal Work Manufacturing
SIC 3444: Sheet Metal Work
Sales Range $5
M
to 10
M
# of Employees 33
Plant Area 210,830
ft2
Annual Production 68,000
units
Production Hrs. Annual 2,600
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $95,379 769,187
kWh
Natural Gas $21,828 2,547
MMBtu
Waste Disposal Costs
Water Usage $1,284 380
Tgal
Water Disposal $5,031 380
Tgal
TOTAL YEARLY COSTS $123,522
RECOMMENDED SAVINGS* $50,904 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Fees Savings Administrative Changes Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $641 $985 $641
5,166
kWh
- -
02 2.7135: Install occupancy sensors $520 $1,286 $520
4,192
kWh
- -
03 2.9114: Use solar heat to make electricty $31,249 $160,056 $31,249
252,010
kWh
- -
04 2.3212: Optimize plant power factor $3,482 $11,190 - $3,482 -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,886 $1,320 $1,886
15,210
kWh
- -
06 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $8,920 $6,940 $8,920
71,933
kWh
- -
07 2.8112: Combine utility meters $682 $80 - - $682
08 2.6211: Conserve energy by efficient use of vending machines $558 $410 $558
4,501
kWh
- -
09 2.7212: Install or upgrade insulation on hvac distribution systems $1,109 $2,120 $1,109
8,942
kWh
- -
10 2.7211: Clean and maintain refrigerant condensers and towers $1,857 $3,900 $1,857
14,976
kWh
- -
TOTAL RECOMMENDED $50,904 $188,287 $46,740
376,930
kWh
$3,482 $682
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Fees Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs