Assessment Year | 2025 |
---|---|
Principal Product | welded and machined enclosures |
NAICS | 332322: Sheet Metal Work Manufacturing |
SIC | 3444: Sheet Metal Work |
Sales Range | $5 M to 10M |
# of Employees | 33 |
Plant Area |
210,830
ft2
|
Annual Production | 68,000
units
|
Production Hrs. Annual | 2,600
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $95,379 | 769,187 |
kWh
|
$0.12 | |
Natural Gas | $21,828 | 2,547 |
MMBtu
|
$8.57 | |
Waste Disposal Costs | |||||
Water Usage | $1,284 | 380 |
Tgal
|
$3.38 | |
Water Disposal | $5,031 | 380 |
Tgal
|
$13.24 | |
TOTAL YEARLY COSTS | $123,522 | ||||
RECOMMENDED SAVINGS* | $50,904 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $641 | $985 |
$641
5,166
kWh
|
- | - | |
02 | 2.7135: Install occupancy sensors | $520 | $1,286 |
$520
4,192
kWh
|
- | - | |
03 | 2.9114: Use solar heat to make electricty | $31,249 | $160,056 |
$31,249
252,010
kWh
|
- | - | |
04 | 2.3212: Optimize plant power factor | $3,482 | $11,190 | - | $3,482 | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,886 | $1,320 |
$1,886
15,210
kWh
|
- | - | |
06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $8,920 | $6,940 |
$8,920
71,933
kWh
|
- | - | |
07 | 2.8112: Combine utility meters | $682 | $80 | - | - | $682 | |
08 | 2.6211: Conserve energy by efficient use of vending machines | $558 | $410 |
$558
4,501
kWh
|
- | - | |
09 | 2.7212: Install or upgrade insulation on hvac distribution systems | $1,109 | $2,120 |
$1,109
8,942
kWh
|
- | - | |
10 | 2.7211: Clean and maintain refrigerant condensers and towers | $1,857 | $3,900 |
$1,857
14,976
kWh
|
- | - | |
TOTAL RECOMMENDED | $50,904 | $188,287 |
$46,740
376,930
kWh
|
$3,482 | $682 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs