| Assessment Year | 2024 |
|---|---|
| Principal Product | Copper Bus bars, Connectors, Terminal Plates |
| NAICS | 335931: Current-Carrying Wiring Device Manufacturing |
| SIC | 3643: Current-Carrying Wiring Devices |
| Sales Range | $10 M to 50M |
| # of Employees | 95 |
| Plant Area |
65,000
ft2
|
| Annual Production | 1,772,111
pieces
|
| Production Hrs. Annual | 4,160
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $98,388 | 1,012,860 |
kWh
|
$0.097 | |
| Electricity Demand | $42,027 | 4,452 |
kW-mo/yr
|
$9.44 | |
| Natural Gas | $37,486 | 4,487 |
MMBtu
|
$8.35 | |
| Waste Disposal Costs | |||||
| Water Usage | $4,796 | 1,429 |
Tgal
|
$3.36 | |
| Water Disposal | $16,139 | 1,429 |
Tgal
|
$11.29 | |
| TOTAL YEARLY COSTS | $198,836 | ||||
| RECOMMENDED SAVINGS* | $51,894 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | $17,519 | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $878 | $1,370 |
$689
7,104
kWh
|
$189
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.9114: Use solar heat to make electricty | $23,461 | $163,800 |
$23,461
241,864
kWh
|
- | - | - | - | |
| 03 | 2.3212: Optimize plant power factor | $5,711 | $4,416 | - | - | $5,711 | - | - | |
| 04 | 2.8117: Install sub-metering equipment | $677 | $990 | - | - | - | - | $677 | |
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $10,253 | $7,180 |
$10,253
105,700
kWh
|
- | - | - | - | |
| 06 | 2.7231: Use radiant heater for spot heating | $10,095 | $25,179 | - | - | - |
$10,095
-
MMBtu
|
- | |
| 07 | 2.6211: Conserve energy by efficient use of vending machines | $819 | $480 |
$819
8,439
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $51,894 | $203,415 |
$35,222
363,107
kWh
|
$189
-
kW-mo/yr
|
$5,711 |
$10,095
-
MMBtu
|
$677 | ||
| TOTAL IMPLEMENTED | $17,519 | $13,956 |
$10,942
112,804
kWh
|
$189
-
kW-mo/yr
|
$5,711 | - | $677 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs