Assessment Year | 2024 |
---|---|
Principal Product | RF & EM Absorbers |
NAICS | 334419: Other Electronic Component Manufacturing |
SIC | 3679: Electronic Components, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 45 |
Plant Area |
100,000
ft2
|
Annual Production | 7,800
units
|
Production Hrs. Annual | 4,940
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $256,123 | 3,353,600 |
kWh
|
$0.076 | |
Electricity Demand | $48,281 | 6,680 |
kW-mo/yr
|
$7.23 | |
Natural Gas | $190,566 | 31,761 |
MMBtu
|
$6.00 | |
Waste Disposal Costs | |||||
Water Usage | $4,636 | 1,159 |
Tgal
|
$4.00 | |
Water Disposal | $5,795 | 1,159 |
Tgal
|
$5.00 | |
TOTAL YEARLY COSTS | $505,401 | ||||
RECOMMENDED SAVINGS* | $31,908 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|
01 | 2.7211: Clean and maintain refrigerant condensers and towers | $3,139 | $4,760 |
$3,139
41,295
kWh
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,798 | $1,675 |
$1,798
23,653
kWh
|
- | - | |
03 | 2.9114: Use solar heat to make electricty | $25,346 | $210,600 |
$25,346
333,493
kWh
|
- | - | |
04 | 2.8117: Install sub-metering equipment | $1,500 | $1,100 | - | - | $1,500 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $125 | $611 |
$87
1,149
kWh
|
$38
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $31,908 | $218,746 |
$30,370
399,590
kWh
|
$38
-
kW-mo/yr
|
$1,500 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs