Assessment Year | 2024 |
---|---|
Principal Product | Processed meat |
NAICS | 311612: Meat Processed from Carcasses |
SIC | 2011: Meat Packing Plants |
Sales Range | $5 M to 10M |
# of Employees | 17 |
Plant Area |
25,000
ft2
|
Annual Production | 2,285,000
lb
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $77,972 | 1,528,863 |
kWh
|
$0.051 | |
Electricity Demand | $39,937 | 4,030 |
kW-mo/yr
|
$9.91 | |
LPG | $33,468 | 1,279 |
MMBtu
|
$26.17 | |
Waste Disposal Costs | |||||
Water Usage | $10,966 | 1,129 |
Tgal
|
$9.71 | |
TOTAL YEARLY COSTS | $162,343 | ||||
RECOMMENDED SAVINGS* | $18,343 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $89 | - |
$89
1,746
kWh
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,987 | $1,552 |
$3,987
78,178
kWh
|
|
03 | 2.9114: Use solar heat to make electricty | $14,088 | $189,810 |
$14,088
276,226
kWh
|
|
04 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $179 | $580 |
$179
3,515
kWh
|
|
TOTAL RECOMMENDED | $18,343 | $191,942 |
$18,343
359,665
kWh
|
||
TOTAL IMPLEMENTED | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs