| Assessment Year | 2023 |
|---|---|
| Principal Product | potable water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $5 M to 10M |
| # of Employees | 8 |
| Plant Area |
22,100
ft2
|
| Annual Production | 1,800,000
Tgal
|
| Production Hrs. Annual | 8,736
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $181,311 | 2,568,725 |
kWh
|
$0.071 |
| Electricity Demand | $49,996 | 4,500 |
kW-mo/yr
|
$11.11 |
| Natural Gas | $2,210 | 260 |
MMBtu
|
$8.50 |
| TOTAL YEARLY COSTS | $233,517 | |||
| RECOMMENDED SAVINGS* | $31,189 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $310 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.3322: Use existing dam to generate electricity | $9,070 | $42,900 |
$9,070
127,746
kWh
|
- | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,461 | $2,074 |
$2,025
28,514
kWh
|
$436
-
kW-mo/yr
|
|
| 03 | 2.7211: Clean and maintain refrigerant condensers and towers | $310 | $291 |
$310
4,368
kWh
|
- | |
| 04 | 2.9114: Use solar heat to make electricty | $19,348 | $189,810 |
$19,348
272,514
kWh
|
- | |
| TOTAL RECOMMENDED | $31,189 | $235,075 |
$30,753
433,142
kWh
|
$436
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | $310 | $291 |
$310
4,368
kWh
|
- | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs