Assessment Year | 2021 |
---|---|
Principal Product | Architectural fencing |
NAICS | 332323: Ornamental and Architectural Metal Work Manufacturing |
SIC | 3446: Architectural and Ornamental Metal Work |
Sales Range | $100 M to 500M |
# of Employees | 523 |
Plant Area |
696,530
ft2
|
Annual Production | 60,000
ton
|
Production Hrs. Annual | 2,340
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $994,163 | 18,757,788 |
kWh
|
$0.053 | |
Electricity Demand | $464,296 | 58,402 |
kW-mo/yr
|
$7.95 | |
Natural Gas | $464,451 | 171,384 |
MMBtu
|
$2.71 | |
Waste Disposal Costs | |||||
Water Usage | $66,394 | 27,080 |
Tgal
|
$2.45 | |
TOTAL YEARLY COSTS | $1,989,304 | ||||
RECOMMENDED SAVINGS* | $114,669 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $6,075 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $83,427 | $407,400 | - | - | $83,427 | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $25,167 | $70,338 |
$15,961
301,142
kWh
|
$9,206
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,923 | $2,911 |
$3,923
74,013
kWh
|
- | - | - | |
04 | 2.2437: Recover waste heat from equipment | $2,152 | $4,457 | - | - | - |
$2,152
-
MMBtu
|
|
TOTAL RECOMMENDED | $114,669 | $485,106 |
$19,884
375,155
kWh
|
$9,206
-
kW-mo/yr
|
$83,427 |
$2,152
-
MMBtu
|
||
TOTAL IMPLEMENTED | $6,075 | $7,368 |
$3,923
74,013
kWh
|
- | - |
$2,152
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs