Assessment Year | 2020 |
---|---|
Principal Product | Treated wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $500 k to 1M |
# of Employees | 37 |
Plant Area |
193,522
ft2
|
Annual Production | 109,500
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $69,967 | 925,488 |
kWh
|
$0.076 | |
Electricity Demand | $23,681 | 1,986 |
kW-mo/yr
|
$11.92 | |
Electricity Fees | $1,092 | - |
|
- | |
Natural Gas | $2,041 | 422 |
MMBtu
|
$4.84 | |
Waste Disposal Costs | |||||
Water Usage | $8,114 | 678 |
Tgal
|
$11.97 | |
TOTAL YEARLY COSTS | $104,895 | ||||
RECOMMENDED SAVINGS* | $17,047 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $11,814 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $6,099 | $5,247 |
$6,099
80,669
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,472 | $6,388 |
$3,472
45,920
kWh
|
- | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,459 | $8,757 |
$2,759
36,498
kWh
|
$700
-
kW-mo/yr
|
|
04 | 2.4322: Use or replace with energy efficient substitutes | $2,243 | $4,000 |
$2,243
29,667
kWh
|
- | |
05 | 2.7224: Reduce space conditioning during non-working hours | $1,774 | - |
$1,774
23,468
kWh
|
- | |
TOTAL RECOMMENDED | $17,047 | $24,392 |
$16,347
216,222
kWh
|
$700
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $11,814 | $15,635 |
$11,814
156,256
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs