Assessment Year | 2020 |
---|---|
Principal Product | Treated wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $5 M to 10M |
# of Employees | 10 |
Plant Area |
897,697
ft2
|
Annual Production | 1,825,000
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $327,036 | 4,955,085 |
kWh
|
$0.066 | |
Electricity Demand | $79,320 | 11,380 |
kW-mo/yr
|
$6.97 | |
Natural Gas | $20,794 | 5,941 |
MMBtu
|
$3.50 | |
Waste Disposal Costs | |||||
Water Usage | $120,702 | 15,696 |
Tgal
|
$7.69 | |
TOTAL YEARLY COSTS | $547,852 | ||||
RECOMMENDED SAVINGS* | $96,448 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Usage Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $12,533 | $4,129 |
$12,533
189,895
kWh
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,018 | $7,359 |
$3,018
45,731
kWh
|
- | |
03 | 2.7135: Install occupancy sensors | $629 | $387 |
$629
9,531
kWh
|
- | |
04 | 3.4111: Use closed cycle process to minimize waste water production | $80,268 | $2,200 | - |
$80,268
-
Tgal
|
|
TOTAL RECOMMENDED | $96,448 | $14,075 |
$16,180
245,157
kWh
|
$80,268
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs