ITAC Assessment: OK0945
ITAC logo
ITAC Assessment: OK0945
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2016
Principal Product Products of purchased glass
NAICS 327215: Glass Product Manufacturing Made of Purchased Glass
SIC 3231: Glass Products, Made of Purchased Glass
Sales Range $10
M
to 50
M
# of Employees 140
Plant Area 145,000
ft2
Annual Production 20,000,000
lb
Production Hrs. Annual 7,248
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $186,874 3,664,200
kWh
Electricity Demand $210,265 17,031
kW-mo/yr
Natural Gas $5,176 634
MMBtu
TOTAL YEARLY COSTS $402,315
RECOMMENDED SAVINGS* $62,186 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $21,559

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.3212: Optimize plant power factor $23,818 $29,535 - - $23,818
02 2.4231: Reduce the pressure of compressed air to the minimum required $2,229 - $2,229
43,372
kWh
- -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $21,559 $26,380 $15,423
300,067
kWh
$6,136
-
kW-mo/yr
-
04 2.2511: Insulate bare equipment $14,580 $10,000 $10,431
202,944
kWh
$4,148
-
kW-mo/yr
-
TOTAL RECOMMENDED $62,186 $65,915 $28,083
546,383
kWh
$10,284
-
kW-mo/yr
$23,818
TOTAL IMPLEMENTED $21,559 $26,380 $15,423
300,067
kWh
$6,136
-
kW-mo/yr
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs