Assessment Year | 2015 |
---|---|
Principal Product | Recycled plastic building products |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 30 |
Plant Area |
40,000
ft2
|
Annual Production | 20,000,000
lb
|
Production Hrs. Annual | 8,184
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,105,464 | 15,837,600 |
kWh
|
$0.070 |
Electricity Demand | $74,033 | 33,288 |
kW-mo/yr
|
$2.22 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $158,584 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $4,131 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.4133: Use most efficient type of electric motors | $137,102 | $90,000 |
$128,855
1,846,065
kWh
|
$8,247
-
kW-mo/yr
|
- | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $17,351 | $10,800 |
$17,351
248,583
kWh
|
- | - | |
03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,131 | - | - | - | $4,131 | |
TOTAL RECOMMENDED | $158,584 | $100,800 |
$146,206
2,094,648
kWh
|
$8,247
-
kW-mo/yr
|
$4,131 | ||
TOTAL IMPLEMENTED | $4,131 | - | - | - | $4,131 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs