| Assessment Year | 2015 |
|---|---|
| Principal Product | Recycled plastic building products |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 30 |
| Plant Area |
40,000
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 8,184
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,105,464 | 15,837,600 |
kWh
|
$0.070 |
| Electricity Demand | $74,033 | 33,288 |
kW-mo/yr
|
$2.22 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $158,584 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,131 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.4133: Use most efficient type of electric motors | $137,102 | $90,000 |
$128,855
1,846,065
kWh
|
$8,247
-
kW-mo/yr
|
- | |
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $17,351 | $10,800 |
$17,351
248,583
kWh
|
- | - | |
| 03 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $4,131 | - | - | - | $4,131 | |
| TOTAL RECOMMENDED | $158,584 | $100,800 |
$146,206
2,094,648
kWh
|
$8,247
-
kW-mo/yr
|
$4,131 | ||
| TOTAL IMPLEMENTED | $4,131 | - | - | - | $4,131 | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs