Assessment Year | 2015 |
---|---|
Principal Product | Recycled plastic building products |
NAICS | 326199: All Other Plastics Product Manufacturing |
SIC | 3999: Manufacturing Industries, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 80 |
Plant Area |
50,000
ft2
|
Annual Production | 31,200,000
lb
|
Production Hrs. Annual | 8,184
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $381,690 | 7,758,600 |
kWh
|
$0.049 |
Electricity Demand | $205,985 | 30,925 |
kW-mo/yr
|
$6.66 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $117,729 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $26,164 | $68,769 | - | - | $26,164 | |
02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $9,329 | $20,400 |
$9,329
187,700
kWh
|
- | - | |
03 | 2.4133: Use most efficient type of electric motors | $82,236 | $72,000 |
$68,618
1,380,641
kWh
|
$13,618
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $117,729 | $161,169 |
$77,947
1,568,341
kWh
|
$13,618
-
kW-mo/yr
|
$26,164 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs