Assessment Year | 2014 |
---|---|
Principal Product | Investment castings |
NAICS | 331523: Nonferrous Metal Die-Casting Foundries |
SIC | 3324: Steel Investment Foundries |
Sales Range | $5 M to 10M |
# of Employees | 54 |
Plant Area |
20,000
ft2
|
Annual Production | 28,600
pieces
|
Production Hrs. Annual | 5,850
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $185,308 | 1,546,500 |
kWh
|
$0.12 |
Natural Gas | $30,563 | 6,728 |
MMBtu
|
$4.54 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $62,962 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,107 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $23,245 | - |
$23,245
193,708
kWh
|
- | |
02 | 2.4322: Use or replace with energy efficient substitutes | $2,223 | $1,540 |
$2,223
18,528
kWh
|
- | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,460 | $2,969 |
$11,460
95,500
kWh
|
- | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $652 | $3,540 |
$652
5,437
kWh
|
- | |
05 | 2.7241: Install outside air damper / economizer on hvac unit | $8,810 | $4,000 |
$8,810
73,416
kWh
|
- | |
06 | 2.7211: Clean and maintain refrigerant condensers and towers | $52 | $30 |
$52
430
kWh
|
- | |
07 | 2.7224: Reduce space conditioning during non-working hours | $700 | $120 | - |
$700
-
MMBtu
|
|
08 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $487 | $1,834 |
$487
4,057
kWh
|
- | |
09 | 2.1135: Repair furnaces and oven doors so that they seal efficiently | $2,159 | $1,600 | - |
$2,159
-
MMBtu
|
|
10 | 2.2437: Recover waste heat from equipment | $6,815 | $55,000 | - |
$6,815
-
MMBtu
|
|
11 | 2.2414: Use waste heat from hot flue gases to preheat | $3,984 | $17,104 | - |
$3,984
-
MMBtu
|
|
12 | 2.2414: Use waste heat from hot flue gases to preheat | $2,375 | $5,900 | - |
$2,375
-
MMBtu
|
|
TOTAL RECOMMENDED | $62,962 | $93,636 |
$46,929
391,077
kWh
|
$16,033
-
MMBtu
|
||
TOTAL IMPLEMENTED | $26,107 | $5,170 |
$23,949
199,575
kWh
|
$2,159
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs