Assessment Year | 2014 |
---|---|
Principal Product | Parking Meters |
NAICS | 334514: Totalizing Fluid Meter and Counting Device Manufacturing |
SIC | 3824: Totalizing Fluid Meters and Counting Devices |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
57,000
ft2
|
Annual Production | 10,000
pieces
|
Production Hrs. Annual | 4,125
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $69,870 | 838,400 |
kWh
|
$0.083 |
Electricity Demand | $15,631 | 4,895 |
kW-mo/yr
|
$3.19 |
Natural Gas | $77,383 | 10,037 |
MMBtu
|
$7.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $58,348 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,084 | $3,640 |
$8,197
98,400
kWh
|
$887
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $681 | $1,600 |
$566
6,800
kWh
|
$115
-
kW-mo/yr
|
- | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,306 | $530 |
$1,216
14,600
kWh
|
$89
-
kW-mo/yr
|
- | - | - | |
04 | 2.2511: Insulate bare equipment | $870 | $830 |
$870
10,430
kWh
|
- | - | - | - | |
05 | 2.8114: Change rate schedules or other changes in utility service | $168 | $15 | - | - | $168 | - | - | |
06 | 2.4239: Eliminate or reduce compressed air usage | $3,040 | $645 |
$3,040
36,500
kWh
|
- | - | - | - | |
07 | 2.8114: Change rate schedules or other changes in utility service | $1,400 | $30 | - | - | - | - | $1,400 | |
08 | 2.4322: Use or replace with energy efficient substitutes | $41,800 | $54,000 | - | - | - |
$41,800
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $58,348 | $61,290 |
$13,889
166,730
kWh
|
$1,091
-
kW-mo/yr
|
$168 |
$41,800
-
MMBtu
|
$1,400 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs