ITAC Assessment: OK0854
ITAC logo
ITAC Assessment: OK0854
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2013
Principal Product Solid waste processing equipment
NAICS 333318: Other Commercial and Service Industry Machinery Manufacturing
SIC 3589: Service Industry Machinery, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 170
Plant Area 80,000
ft2
Annual Production 2,200
pieces
Production Hrs. Annual 4,590
hrs
Location (State) Arkansas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $68,067 1,284,285
kWh
Electricity Demand $65,071 6,215
kW-mo/yr
Natural Gas $29,996 3,353
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $30,085 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $7,346

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.8121: Apply for tax-free status for energy purchases $3,342 - - - $3,342
02 2.3212: Optimize plant power factor $3,180 $6,300 - - $3,180
03 2.7135: Install occupancy sensors $1,391 $2,535 $1,391
26,390
kWh
- -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,783 $1,188 $1,783
33,826
kWh
- -
05 2.4231: Reduce the pressure of compressed air to the minimum required $830 - $600
11,400
kWh
$230
-
kW-mo/yr
-
06 2.4322: Use or replace with energy efficient substitutes $19,559 $94,000 $9,424
164,521
kWh
$10,135
-
kW-mo/yr
-
TOTAL RECOMMENDED $30,085 $104,023 $13,198
236,137
kWh
$10,365
-
kW-mo/yr
$6,522
TOTAL IMPLEMENTED $7,346 $3,723 $3,774
71,616
kWh
$230
-
kW-mo/yr
$3,342
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs