Assessment Year | 2012 |
---|---|
Principal Product | Shape wear |
NAICS | 315210: Cut and Sew Apparel Contractors |
SIC | 2341: Women's, Misses', Children's, and Infants' Underwear and Nightwear |
Sales Range | $50 M to 100M |
# of Employees | 147 |
Plant Area |
130,000
ft2
|
Annual Production | 715,000
pieces
|
Production Hrs. Annual | 2,730
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $116,376 | 1,191,600 |
kWh
|
$0.098 |
Natural Gas | $43,042 | 5,268 |
MMBtu
|
$8.17 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $61,667 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $10,291 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.7226: Use computer programs to optimize hvac performance | $17,721 | $31,152 |
$9,110
93,922
kWh
|
$8,611
-
MMBtu
|
|
02 | 2.7241: Install outside air damper / economizer on hvac unit | $21,096 | $22,080 |
$21,096
217,486
kWh
|
- | |
03 | 2.7243: Improve air circulation with destratification fans / other methods | $9,127 | $23,400 |
$1,693
17,454
kWh
|
$7,434
-
MMBtu
|
|
04 | 2.7135: Install occupancy sensors | $2,183 | $8,237 |
$2,183
22,512
kWh
|
- | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,772 | $8,055 |
$2,772
28,578
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $787 | $4,095 |
$787
8,117
kWh
|
- | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $687 | $1,691 |
$687
7,092
kWh
|
- | |
08 | 2.7492: Use proper thickness of insulation on building envelope | $6,045 | $162,500 |
$679
7,005
kWh
|
$5,366
-
MMBtu
|
|
09 | 2.2437: Recover waste heat from equipment | $1,249 | $461 | - |
$1,249
-
MMBtu
|
|
TOTAL RECOMMENDED | $61,667 | $261,671 |
$39,007
402,166
kWh
|
$22,660
-
MMBtu
|
||
TOTAL IMPLEMENTED | $10,291 | $176,341 |
$4,925
50,792
kWh
|
$5,366
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs