ITAC Assessment: OK0817
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2011
Principal Product Filters
NAICS 333413: Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing
SIC 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment
Sales Range $10
M
to 50
M
# of Employees 250
Plant Area 475,000
ft2
Annual Production 5,200,000
pieces
Production Hrs. Annual 8,760
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $280,627 4,088,560
kWh
Natural Gas $26,063 4,305
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $65,403 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $14,820

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,438 $510 $6,438
93,852
kWh
-
02 2.2437: Recover waste heat from equipment $1,812 $1,220 - $1,812
-
MMBtu
03 2.4231: Reduce the pressure of compressed air to the minimum required $1,613 $2,745 $1,613
23,526
kWh
-
04 2.7142: Utilize higher efficiency lamps and/or ballasts $728 $2,751 $728
10,612
kWh
-
05 2.7142: Utilize higher efficiency lamps and/or ballasts $29,469 $55,540 $29,469
429,581
kWh
-
06 2.7142: Utilize higher efficiency lamps and/or ballasts $12,965 $47,375 $12,965
189,000
kWh
-
07 2.7243: Improve air circulation with destratification fans / other methods $5,011 $23,400 $755
11,003
kWh
$4,256
-
MMBtu
08 2.2691: Shut off cooling if cold outside air will cool process $2,546 $12,837 $2,546
37,121
kWh
-
09 2.7241: Install outside air damper / economizer on hvac unit $1,450 $4,260 $1,450
21,141
kWh
-
10 2.6212: Turn off equipment during breaks, reduce operating time $3,371 - $3,371
49,140
kWh
-
TOTAL RECOMMENDED $65,403 $150,638 $59,335
864,976
kWh
$6,068
-
MMBtu
TOTAL IMPLEMENTED $14,820 $23,910 $10,564
153,995
kWh
$4,256
-
MMBtu
Yearly Savings* Imp'd Cost* Electricity Usage Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs