Assessment Year | 2011 |
---|---|
Principal Product | Paperboard boxes |
NAICS | 322212: Folding Paperboard Box Manufacturing |
SIC | 2657: Folding Paperboard Boxes, Including Sanitary |
Sales Range | $100 M to 500M |
# of Employees | 285 |
Plant Area |
350,000
ft2
|
Annual Production | 150,000,000
pieces
|
Production Hrs. Annual | 8,640
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $662,120 | 12,064,816 |
kWh
|
$0.055 |
Natural Gas | $103,209 | 10,666 |
MMBtu
|
$9.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $98,240 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $50,157 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.5113: Use direct flame impingement or infrared processing for chamber type heating | $41,808 | $12,400 | - | - |
$41,808
-
MMBtu
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $44,840 | $11,400 |
$44,840
815,237
kWh
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,360 | $14,062 |
$3,360
80,015
kWh
|
- | - | |
04 | 2.7124: Make a practice of turning off lights when not needed | $5,317 | - |
$5,317
126,590
kWh
|
- | - | |
05 | 2.3132: Recharge batteries on during off-peak demand periods | $2,915 | - | - |
$2,915
-
kW-mo/yr
|
- | |
TOTAL RECOMMENDED | $98,240 | $37,862 |
$53,517
1,021,842
kWh
|
$2,915
-
kW-mo/yr
|
$41,808
-
MMBtu
|
||
TOTAL IMPLEMENTED | $50,157 | $11,400 |
$50,157
941,827
kWh
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs