Assessment Year | 2011 |
---|---|
Principal Product | Tools |
NAICS | 333991: Power-Driven Handtool Manufacturing |
SIC | 3546: Power-Driven Handtools |
Sales Range | $10 M to 50M |
# of Employees | 545 |
Plant Area |
300,000
ft2
|
Annual Production | 40,000,000
pieces
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,707,628 | 38,815,200 |
kWh
|
$0.044 |
Electricity Demand | $516,060 | 86,216 |
kW-mo/yr
|
$5.99 |
Natural Gas | $755,204 | 129,333 |
MMBtu
|
$5.84 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $302,966 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $263,668 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.1116: Improve combustion control capability | $165,120 | $3,385 | - |
$165,120
-
MMBtu
|
|
02 | 2.2121: Increase amount of condensate returned | $21,982 | $8,893 | - |
$21,982
-
MMBtu
|
|
03 | 2.6218: Turn off equipment when not in use | $98,548 | $15,600 |
$98,548
2,270,688
kWh
|
- | |
04 | 2.7231: Use radiant heater for spot heating | $17,316 | $4,650 | - |
$17,316
-
MMBtu
|
|
TOTAL RECOMMENDED | $302,966 | $32,528 |
$98,548
2,270,688
kWh
|
$204,418
-
MMBtu
|
||
TOTAL IMPLEMENTED | $263,668 | $18,985 |
$98,548
2,270,688
kWh
|
$165,120
-
MMBtu
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs