| Assessment Year | 2009 |
|---|---|
| Principal Product | MUSHROOMS |
| NAICS | 311991: Perishable Prepared Food Manufacturing |
| SIC | 2099: Food Preparations, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 180 |
| Plant Area |
388,000
ft2
|
| Annual Production | 20,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $664,420 | 12,383,980 |
kWh
|
$0.054 |
| Natural Gas | $712,234 | 74,278 |
MMBtu
|
$9.59 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $193,402 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $193,402 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|
| 01 | 4.652: Replace existing equipment with more suitable substitutes | $171,482 | $47,731 |
$20,722
357,855
kWh
|
$146,520
-
MMBtu
|
$4,240
-
Tgal
|
|
| 02 | 2.2136: Install / repair insulation on steam lines | $4,464 | $1,266 | - |
$4,464
-
MMBtu
|
- | |
| 03 | 2.2135: Repair and eliminate steam leaks | $13,933 | $525 | - |
$13,933
-
MMBtu
|
- | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,111 | $5,417 |
$3,111
74,460
kWh
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $412 | - |
$412
7,674
kWh
|
- | - | |
| TOTAL RECOMMENDED | $193,402 | $54,939 |
$24,245
439,989
kWh
|
$164,917
-
MMBtu
|
$4,240
-
Tgal
|
||
| TOTAL IMPLEMENTED | $193,402 | $54,939 |
$24,245
439,989
kWh
|
$164,917
-
MMBtu
|
$4,240
-
Tgal
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs