| Assessment Year | 2006 |
|---|---|
| Principal Product | PVC Resin |
| NAICS | 325211: Plastics Material and Resin Manufacturing |
| SIC | 2821: Plastics Materials, Synthetic Resins, and Nonvulcanizable Elastomers |
| Sales Range | $100 M to 500M |
| # of Employees | 100 |
| Plant Area |
100,000
ft2
|
| Annual Production | 500,000,000
lb
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $907,992 | 133,150 |
kWh
|
$6.82 |
| Electricity Demand | $333,533 | 62,512 |
kW-mo/yr
|
$5.34 |
| Natural Gas | $3,996,595 | 202,258 |
MMBtu
|
$19.76 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $181,880 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.2163: Use minimum steam operating pressure | $22,707 | $1,420 | - | - |
$22,707
-
MMBtu
|
|
| 02 | 2.2121: Increase amount of condensate returned | $7,798 | $11,625 | - | - |
$7,798
-
MMBtu
|
|
| 03 | 2.2113: Repair or replace steam traps | $92,687 | $1,025 | - | - |
$92,687
-
MMBtu
|
|
| 04 | 2.4239: Eliminate or reduce compressed air usage | $30,440 | $19,260 |
$23,884
628,530
kWh
|
$6,556
-
kW-mo/yr
|
- | |
| 05 | 2.2611: Moderate cooling tower outlet temperature | $28,248 | $15,000 |
$28,248
743,374
kWh
|
- | - | |
| TOTAL RECOMMENDED | $181,880 | $48,330 |
$52,132
1,371,904
kWh
|
$6,556
-
kW-mo/yr
|
$123,192
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs