| Assessment Year | 2006 |
|---|---|
| Principal Product | Poultry Products |
| NAICS | 311615: Poultry Processing |
| SIC | 2015: Poultry Slaughtering and Processing |
| Sales Range | $100 M to 500M |
| # of Employees | 620 |
| Plant Area |
69,091
ft2
|
| Annual Production | 400,000,000
lb
|
| Production Hrs. Annual | 7,488
hrs
|
| Location (State) | Arkansas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $357,023 | 10,610,775 |
kWh
|
$0.034 |
| Electricity Demand | $221,790 | 20,370 |
kW-mo/yr
|
$10.89 |
| Electricity Fees | $17,334 | - |
|
- |
| Natural Gas | $205,796 | 29,337 |
MMBtu
|
$7.01 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $78,490 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|
| 01 | 2.3212: Optimize plant power factor | $36,035 | $14,223 | - | $36,035 | - | |
| 02 | 2.2511: Insulate bare equipment | $1,143 | $339 | - | - |
$1,143
-
MMBtu
|
|
| 03 | 2.7135: Install occupancy sensors | $365 | $437 |
$365
10,483
kWh
|
- | - | |
| 04 | 2.2437: Recover waste heat from equipment | $29,580 | $24,609 | - | - |
$29,580
-
MMBtu
|
|
| 05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $11,367 | $27,265 |
$11,367
326,633
kWh
|
- | - | |
| TOTAL RECOMMENDED | $78,490 | $66,873 |
$11,732
337,116
kWh
|
$36,035 |
$30,723
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs