Assessment Year | 2008 |
---|---|
Principal Product | Oil and gas well wellheads and subsea trees |
NAICS | 333132: Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533: Oil and Gas Field Machinery and Equipment |
Sales Range | $100 M to 500M |
# of Employees | 450 |
Plant Area |
462,700
ft2
|
Annual Production | 36,000
ton
|
Production Hrs. Annual | 7,120
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,586,268 | 18,178,638 |
kWh
|
$0.087 |
Electricity Demand | $243,525 | 35,249 |
kW-mo/yr
|
$6.91 |
Electricity Fees | $12,859 | - |
|
- |
Natural Gas | $109,118 | 12,261 |
MMBtu
|
$8.90 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $176,700 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $95,030 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $72,200 | $85,400 |
$65,700
738,700
kWh
|
$6,500
-
kW-mo/yr
|
|
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $8,300 | $1,000 |
$7,550
84,800
kWh
|
$750
-
kW-mo/yr
|
|
03 | 2.6218: Turn off equipment when not in use | $80,000 | - |
$80,000
898,000
kWh
|
- | |
04 | 2.7124: Make a practice of turning off lights when not needed | $8,050 | - |
$7,270
72,400
kWh
|
$780
-
kW-mo/yr
|
|
05 | 2.4239: Eliminate or reduce compressed air usage | $5,260 | $615 |
$5,260
59,000
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,220 | $1,410 |
$1,130
12,750
kWh
|
$90
-
kW-mo/yr
|
|
07 | 2.7145: Install skylights | $1,110 | $1,410 |
$1,110
12,500
kWh
|
- | |
08 | 2.4314: Use synthetic lubricant | $560 | - |
$510
5,700
kWh
|
$50
-
kW-mo/yr
|
|
TOTAL RECOMMENDED | $176,700 | $89,835 |
$168,530
1,883,850
kWh
|
$8,170
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $95,030 | $88,425 |
$86,910
967,650
kWh
|
$8,120
-
kW-mo/yr
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs