ITAC Assessment: OK0715
ITAC logo
ITAC Assessment: OK0715
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2005
Principal Product Aircraft Turbine Repair
NAICS 333999: All Other Miscellaneous General Purpose Machinery Manufacturing
SIC 3599: Industrial and Commercial Machinery and Equipment, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 210
Plant Area 125,000
ft2
Annual Production 120,000
pieces
Production Hrs. Annual 4,160
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $188,204 7,424,000
kWh
Electricity Demand $128,827 19,418
kW-mo/yr
Electricity Fees $90,768 -
Natural Gas $102,653 14,687
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $48,863 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
01 2.4239: Eliminate or reduce compressed air usage $3,938 $3,936 $2,821
111,072
kWh
$1,117
-
kW-mo/yr
-
02 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $6,111 $918 $5,018
197,551
kWh
$1,093
-
kW-mo/yr
-
03 2.4231: Reduce the pressure of compressed air to the minimum required $2,522 $5,175 $2,522
99,308
kWh
- -
04 2.6224: Schedule baking times of small and large components $804 $1,825 - - $804
-
MMBtu
05 2.7241: Install outside air damper / economizer on hvac unit $7,665 $47,100 $7,665
301,786
kWh
- -
06 2.1131: Repair faulty insulation in furnaces, boilers, etc $1,022 $608 $1,022
18,611
kWh
- -
07 2.2628: Utilize a less expensive cooling method $472 $1,000 $472
18,574
kWh
- -
08 2.1321: Replace fossil fuel equipment with electrical equipment $5,361 $26,590 - - $5,361
-
MMBtu
09 2.7221: Lower temperature during the winter season and vice-versa $20,968 - - - $20,968
-
MMBtu
TOTAL RECOMMENDED $48,863 $87,152 $19,520
746,902
kWh
$2,210
-
kW-mo/yr
$27,133
-
MMBtu
TOTAL IMPLEMENTED - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs