Assessment Year | 2003 |
---|---|
Principal Product | Galvanized Steel Products |
NAICS | 332812: Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479: Coating, Engraving, and Allied Services, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 50 |
Plant Area |
30,000
ft2
|
Annual Production | 8,000
ton
|
Production Hrs. Annual | 4,160
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,708 | 567,447 |
kWh
|
$0.042 |
Electricity Fees | $1,807 | - |
|
- |
Natural Gas | $364,342 | 77,422 |
MMBtu
|
$4.71 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,453 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,662 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Fuel Oil #2 Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2414: Use waste heat from hot flue gases to preheat | $16,662 | $13,792 |
$2,744
62,067
kWh
|
$13,918
-
MMBtu
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $748 | - |
$748
16,725
kWh
|
- | - | - | |
03 | 4.611: Begin a practice of predictive / preventative maintenance | $3,400 | - | - | - | - | $3,400 | |
04 | 4.632: Change operating conditions | $28,500 | $40,604 | - | - |
$(-750.0)
-
MMBtu
|
$29,250 | |
05 | 2.7135: Install occupancy sensors | $143 | $184 |
$143
3,195
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $49,453 | $54,580 |
$3,635
81,987
kWh
|
$13,918
-
MMBtu
|
$(-750.0)
-
MMBtu
|
$32,650 | ||
TOTAL IMPLEMENTED | $16,662 | $13,792 |
$2,744
62,067
kWh
|
$13,918
-
MMBtu
|
- | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs