Assessment Year | 2003 |
---|---|
Principal Product | Raw Poultry Products |
NAICS | 311615: Poultry Processing |
SIC | 2015: Poultry Slaughtering and Processing |
Sales Range | $50 M to 100M |
# of Employees | 1,000 |
Plant Area |
106,000
ft2
|
Annual Production | 72,500,000
pieces
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $666,577 | 23,342,200 |
kWh
|
$0.029 |
Electricity Demand | $327,927 | 50,099 |
kW-mo/yr
|
$6.55 |
Electricity Fees | $32,097 | - |
|
- |
Natural Gas | $1,137,569 | 204,145 |
MMBtu
|
$5.57 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $167,463 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $16,412 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $20,939 | $27,543 | - |
$20,939
-
kW-mo/yr
|
- | - | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,120 | - |
$2,786
118,560
kWh
|
$1,334
-
kW-mo/yr
|
- | - | |
03 | 2.2625: Chill water to the highest temperature possible | $12,292 | - |
$9,168
390,135
kWh
|
$3,124
-
kW-mo/yr
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $26,304 | $4,211 | - | - |
$26,304
-
MMBtu
|
- | |
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $43,797 | $113,450 |
$43,797
1,863,175
kWh
|
- | - | - | |
06 | 2.7135: Install occupancy sensors | $1,771 | $1,017 |
$1,771
75,348
kWh
|
- | - | - | |
07 | 4.441: Install automatic packing equipment | $58,240 | $6,500 | - | - | - | $58,240 | |
TOTAL RECOMMENDED | $167,463 | $152,721 |
$57,522
2,447,218
kWh
|
$25,397
-
kW-mo/yr
|
$26,304
-
MMBtu
|
$58,240 | ||
TOTAL IMPLEMENTED | $16,412 | - |
$11,954
508,695
kWh
|
$4,458
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs