Assessment Year | 2002 |
---|---|
Principal Product | Calcined Petroleum Coke |
NAICS |
n/a
|
SIC | 2999: Products of Petroleum and Coal, Not Elsewhere Classified |
Sales Range | $50 M to 100M |
# of Employees | 73 |
Plant Area |
306,000
ft2
|
Annual Production | 500,000
ton
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $251,381 | 8,435,200 |
kWh
|
$0.030 |
Electricity Demand | $121,039 | 122,765 |
kW-mo/yr
|
$0.99 |
Electricity Fees | $2,764 | - |
|
- |
Natural Gas | $777,924 | 151,465 |
MMBtu
|
$5.14 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $5,768,423 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $6,276 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7135: Install occupancy sensors | $1,203 | $1,190 |
$1,203
46,253
kWh
|
- | - | - | - | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $5,073 | $100 |
$3,671
141,193
kWh
|
$1,402
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.2515: Use optimum thickness insulation | $56,715 | $16,956 | n/a | - | - |
$56,715
-
MMBtu
|
- | - | - |
04 | 2.2442: Preheat combustion air with waste heat | $133,632 | $206,750 | - | - |
$133,632
-
MMBtu
|
- | - | - | |
05 | 2.3412: Use waste heat to produce steam to drive a steam turbine-generator | $4,021,800 | $30,000,000 | - | - | - | - | $4,021,800 | - | |
06 | 4.711: Initiate a total quality management program | $1,550,000 | $150,000 | - | - | - | $(-50,000.0) | - | $1,600,000 | |
TOTAL RECOMMENDED | $5,768,423 | $30,374,996 |
$4,874
187,446
kWh
|
$1,402
-
kW-mo/yr
|
$190,347
-
MMBtu
|
$(-50,000.0) | $4,021,800 | $1,600,000 | ||
TOTAL IMPLEMENTED | $6,276 | $1,290 |
$4,874
187,446
kWh
|
$1,402
-
kW-mo/yr
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs