Assessment Year | 1999 |
---|---|
Principal Product | Automobile seals |
NAICS |
n/a
|
SIC | 3052: Rubber and Plastics Hose and Belting |
Sales Range | $10 M to 50M |
# of Employees | 438 |
Plant Area |
150,000
ft2
|
Annual Production | 11,000,000
lb
|
Production Hrs. Annual | 5,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $693,264 | 23,337,632 |
kWh
|
$0.030 |
Electricity Demand | $286,519 | 44,080 |
kW-mo/yr
|
$6.50 |
Natural Gas | $87,827 | 28,331 |
MMBtu
|
$3.10 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $146,134 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.1331: Burn a less expensive grade of fuel | $17,137 | $21,900 | n/a |
$11,351
374,560
kWh
|
$10,380
-
kW-mo/yr
|
$(-4,594.0)
-
MMBtu
|
- | - |
02 | 3.1191: Change procedures / equipment / operating conditions | $2,848 | $2,000 | n/a |
$2,848
94,959
kWh
|
- | - | - | - |
03 | 2.7144: Install spectral reflectors / delamp | $5,367 | $1,070 | n/a |
$3,698
123,388
kWh
|
$1,669
-
kW-mo/yr
|
- | - | - |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $12,573 | $3,864 | n/a |
$8,709
290,445
kWh
|
$3,864
-
kW-mo/yr
|
- | - | - |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,559 | $6,500 | n/a |
$9,336
311,841
kWh
|
$4,223
-
kW-mo/yr
|
- | - | - |
06 | 4.424: Improve space comfort conditioning | $56,000 | $165,000 | n/a | - | - | - | - | $56,000 |
07 | 3.5313: Increase amount of waste recovered for resale | $38,250 | $10,000 | n/a | - | - | - |
$38,250
-
lb
|
- |
08 | 3.5313: Increase amount of waste recovered for resale | $400 | - | n/a | - | - | - |
$400
-
lb
|
- |
TOTAL RECOMMENDED | $146,134 | $210,334 |
$35,942
1,195,193
kWh
|
$20,136
-
kW-mo/yr
|
$(-4,594.0)
-
MMBtu
|
$38,650
-
lb
|
$56,000 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs