| Assessment Year | 1998 |
|---|---|
| Principal Product | Wellhead equipment, gate valves |
| NAICS |
n/a
|
| SIC | 3533: Oil and Gas Field Machinery and Equipment |
| Sales Range | $50 M to 100M |
| # of Employees | 144 |
| Plant Area |
125,000
ft2
|
| Annual Production | 0
units
|
| Production Hrs. Annual | 4,680
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $106,839 | 3,741,208 |
kWh
|
$0.029 |
| Electricity Demand | $78,787 | 8,570 |
kW-mo/yr
|
$9.19 |
| Electricity Fees | $6,300 | - |
|
- |
| Natural Gas | $46,450 | 11,062 |
MMBtu
|
$4.20 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $133,884 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $93,103 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $329 | $1,158 |
$228
7,913
kWh
|
$101
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,641 | $12,354 |
$1,446
50,410
kWh
|
$1,195
-
kW-mo/yr
|
- | - | - | |
| 03 | 4.424: Improve space comfort conditioning | $84,000 | $330,000 | - | - | - | $84,000 | - | |
| 04 | 2.1332: Convert combustion equipment to burn natural gas | $6,750 | $59,000 | - | - | - | - | $6,750 | |
| 05 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $23,508 | $27,000 | - |
$23,508
-
kW-mo/yr
|
- | - | - | |
| 06 | 2.2437: Recover waste heat from equipment | $2,039 | $7,452 |
$2,039
112,837
kWh
|
- | - | - | - | |
| 07 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $7,882 | - | - | - |
$7,882
-
lb
|
- | - | |
| 08 | 3.5316: Contract a wood pallet recycling company | $6,735 | - | - | - |
$6,735
-
lb
|
- | - | |
| TOTAL RECOMMENDED | $133,884 | $436,964 |
$3,713
171,160
kWh
|
$24,804
-
kW-mo/yr
|
$14,617
-
lb
|
$84,000 | $6,750 | ||
| TOTAL IMPLEMENTED | $93,103 | $338,610 |
$2,267
120,750
kWh
|
$101
-
kW-mo/yr
|
$6,735
-
lb
|
$84,000 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs