Assessment Year | 1998 |
---|---|
Principal Product | Computers |
NAICS |
n/a
|
SIC | 3572: Computer Storage Devices |
Sales Range | $100 M to 500M |
# of Employees | 350 |
Plant Area |
150,000
ft2
|
Annual Production | 140,000
units
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $158,316 | 5,555,979 |
kWh
|
$0.028 |
Electricity Demand | $121,457 | 12,783 |
kW-mo/yr
|
$9.50 |
Natural Gas | $107,257 | 27,753 |
MMBtu
|
$3.86 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $64,107 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $54,962 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.7241: Install outside air damper / economizer on hvac unit | $4,481 | $320 | - | - |
$4,481
-
MMBtu
|
- | - | - | |
02 | 2.7135: Install occupancy sensors | $1,223 | $837 |
$1,223
45,135
kWh
|
- | - | - | - | - | |
03 | 2.7111: Reduce illumination to minimum necessary levels | $846 | $300 |
$456
16,706
kWh
|
$208
-
kW-mo/yr
|
- | - | $182 | - | |
04 | 2.4221: Install compressor air intakes in coolest locations | $728 | $548 |
$445
16,413
kWh
|
$283
-
kW-mo/yr
|
- | - | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $196 | $329 |
$86
3,224
kWh
|
$130
-
kW-mo/yr
|
- | - | - | $(-20.0) | |
06 | 4.321: Optimize production lot sizes and inventories | $50,125 | $39,400 | - | - | - | - | $50,125 | - | |
07 | 4.321: Optimize production lot sizes and inventories | $6,348 | - | - | - | - | - | $6,348 | - | |
08 | 3.5313: Increase amount of waste recovered for resale | $160 | - | - | - | - |
$160
-
lb
|
- | - | |
TOTAL RECOMMENDED | $64,107 | $41,734 |
$2,210
81,478
kWh
|
$621
-
kW-mo/yr
|
$4,481
-
MMBtu
|
$160
-
lb
|
$56,655 | $(-20.0) | ||
TOTAL IMPLEMENTED | $54,962 | $40,049 |
$86
3,224
kWh
|
$130
-
kW-mo/yr
|
$4,481
-
MMBtu
|
$160
-
lb
|
$50,125 | $(-20.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs