Assessment Year 1998
Principal Product Frozen dough and apple pies
NAICS
n/a
SIC 2045: Prepared Flour Mixes and Doughs
Sales Range $100
M
to 500
M
# of Employees 160
Plant Area 83,554
ft2
Annual Production 411,000,000
lb
Production Hrs. Annual 6,240
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $296,009 12,531,360
kWh
Electricity Demand $191,129 25,903
kW-mo/yr
Electricity Fees $3,205 -
Natural Gas $13,195 3,003
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $611,384 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $587,623

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Solid Waste (non-haz) Savings Personnel Changes Savings Ancillary Material Cost Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $12,341 $3,402 $(-457.0)
(-15,533)
kWh
$(-214.0)
-
kW-mo/yr
- - $13,100 $(-88.0)
02 2.7144: Install spectral reflectors / delamp $3,965 $200 $3,170
107,562
kWh
$795
-
kW-mo/yr
- - - -
03 2.7142: Utilize higher efficiency lamps and/or ballasts $1,150 $1,450 $289
9,672
kWh
$97
-
kW-mo/yr
- - - $764
04 2.3132: Recharge batteries on during off-peak demand periods $726 $440 - $726
-
kW-mo/yr
- - - -
05 2.7142: Utilize higher efficiency lamps and/or ballasts $401 $1,840 $288
9,672
kWh
$150
-
kW-mo/yr
- - - $(-37.0)
06 2.7135: Install occupancy sensors $155 $396 $155
5,275
kWh
- - - - -
07 4.441: Install automatic packing equipment $574,000 $2,300,000 - - - - $574,000 -
08 3.3122: Use filtration, centrifuging to remove contaminants $18,646 $50,200 - - $(-54.0)
-
Tgal
$24,000
-
lb
$(-5,300.0) -
TOTAL RECOMMENDED $611,384 $2,357,928 $3,445
116,648
kWh
$1,554
-
kW-mo/yr
$(-54.0)
-
Tgal
$24,000
-
lb
$581,800 $639
TOTAL IMPLEMENTED $587,623 $2,306,078 $(-14.0)
(-586)
kWh
$662
-
kW-mo/yr
- - $587,100 $(-125.0)
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Water Disposal Savings Solid Waste (non-haz) Savings Personnel Changes Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs