Assessment Year | 1998 |
---|---|
Principal Product | Structural steel fabrication |
NAICS |
n/a
|
SIC | 3441: Fabricated Structural Metal |
Sales Range | $100 M to 500M |
# of Employees | 165 |
Plant Area |
304,920
ft2
|
Annual Production | 24,000
ton
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $117,802 | 4,347,011 |
kWh
|
$0.027 |
Electricity Demand | $104,073 | 12,264 |
kW-mo/yr
|
$8.49 |
Electricity Fees | $1,620 | - |
|
- |
Natural Gas | $127,098 | 31,118 |
MMBtu
|
$4.08 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $17,855 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.423: Move product using mechanical means | $5,006 | $9,000 | n/a | - | - | - | - | $5,006 | - |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,180 | $2,828 | n/a |
$1,432
48,066
kWh
|
$748
-
kW-mo/yr
|
- | - | - | - |
03 | 2.3212: Optimize plant power factor | $2,129 | - | n/a | - | - | - | - | - | $2,129 |
04 | 2.7135: Install occupancy sensors | $783 | $1,188 | n/a |
$783
29,601
kWh
|
- | - | - | - | - |
05 | 2.1321: Replace fossil fuel equipment with electrical equipment | $1,226 | $5,610 | n/a | - | - |
$1,226
-
MMBtu
|
- | - | - |
06 | 4.423: Move product using mechanical means | $6,531 | - | n/a | - | - | - |
$6,531
-
lb
|
- | - |
TOTAL RECOMMENDED | $17,855 | $18,626 |
$2,215
77,667
kWh
|
$748
-
kW-mo/yr
|
$1,226
-
MMBtu
|
$6,531
-
lb
|
$5,006 | $2,129 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs