Assessment Year | 1997 |
---|---|
Principal Product | Recycled Aluminum |
NAICS |
n/a
|
SIC | 3341: Secondary Smelting and Refining of Nonferrous Metals |
Sales Range | $10 M to 50M |
# of Employees | 61 |
Plant Area |
900,000
ft2
|
Annual Production | 50,000,000
lb
|
Production Hrs. Annual | 7,488
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $124,091 | 4,143,025 |
kWh
|
$0.030 |
Electricity Demand | $87,439 | 9,145 |
kW-mo/yr
|
$9.56 |
Electricity Fees | $2,628 | - |
|
- |
Natural Gas | $702,265 | 265,627 |
MMBtu
|
$2.64 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $53,815 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $18,620 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 4.423: Move product using mechanical means | $22,960 | $110,000 | - | - | - | - | $22,960 | - | |
02 | 2.2414: Use waste heat from hot flue gases to preheat | $14,444 | $17,000 | - | - |
$14,444
-
MMBtu
|
- | - | - | |
03 | 3.4114: Replace city water with recycled water via cooling tower | $11,845 | $8,350 | - | - |
$(-2,018.0)
-
MMBtu
|
$13,863
-
Tgal
|
- | - | |
04 | 2.6218: Turn off equipment when not in use | $3,426 | - |
$7,808
288,101
kWh
|
$(-4,382.0)
-
kW-mo/yr
|
- | - | - | - | |
05 | 3.5316: Contract a wood pallet recycling company | $750 | - | - | - | - | - | - | $750 | |
06 | 2.7135: Install occupancy sensors | $390 | $660 |
$390
14,361
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $53,815 | $136,010 |
$8,198
302,462
kWh
|
$(-4,382.0)
-
kW-mo/yr
|
$12,426
-
MMBtu
|
$13,863
-
Tgal
|
$22,960 | $750 | ||
TOTAL IMPLEMENTED | $18,620 | $17,000 |
$7,808
288,101
kWh
|
$(-4,382.0)
-
kW-mo/yr
|
$14,444
-
MMBtu
|
- | - | $750 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Personnel Changes Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs