ITAC Assessment: OK0524
ITAC logo
ITAC Assessment: OK0524
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1997
Principal Product aluminium die casts
NAICS
n/a
SIC 3633: Household Laundry Equipment
Sales Range $10
M
to 50
M
# of Employees 150
Plant Area 65,000
ft2
Annual Production 4,500,000
lb
Production Hrs. Annual 6,552
hrs
Location (State) Oklahoma

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $116,271 5,182,884
kWh
Electricity Demand $76,614 11,672
kW-mo/yr
Electricity Fees $13,697 -
Natural Gas $169,087 69,971
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $152,944 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Energy Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
01 4.452: Eliminate shift $86,855 $175,000 - - $(-11,425.0)
-
MMBtu
- - $98,280 -
02 2.2442: Preheat combustion air with waste heat $37,293 $65,478 $(-1,889.0)
(-64,185)
kWh
- $39,182
-
MMBtu
- - - -
03 2.1311: Replace electrically-operated equipment with fossil fuel equipment $16,057 $65,478 $14,600
495,018
kWh
$6,566
-
kW-mo/yr
$(-5,109.0)
-
MMBtu
- - - -
04 2.7142: Utilize higher efficiency lamps and/or ballasts $8,530 $80,000 $5,895
199,590
kWh
$2,635
-
kW-mo/yr
- - - - -
05 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $1,329 $90 $1,329
45,135
kWh
- - - - - -
06 3.5316: Contract a wood pallet recycling company $1,056 - - - - - $1,056
-
lb
- -
07 3.6192: Use a less expensive method of waste removal $816 - - - - - $816
-
lb
- -
08 3.5248: Separate and recycle scrap metal to foundry or for sale $741 - - - - - $741
-
lb
- -
09 2.7142: Utilize higher efficiency lamps and/or ballasts $267 $450 $56
1,758
kWh
- - $75
-
MMBtu
- $98 $38
TOTAL RECOMMENDED $152,944 $386,496 $19,991
677,316
kWh
$9,201
-
kW-mo/yr
$22,648
-
MMBtu
$75
-
MMBtu
$2,613
-
lb
$98,378 $38
TOTAL IMPLEMENTED - - - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Natural Gas Savings Other Energy Savings Solid Waste (non-haz) Savings Personnel Changes Savings Administrative Changes Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs