Assessment Year | 1997 |
---|---|
Principal Product | Ceramic Fiber Blanket |
NAICS |
n/a
|
SIC | 3299: Nonmetallic Mineral Products, Not Elsewhere Classified |
Sales Range | $10 M to 50M |
# of Employees | 71 |
Plant Area |
60,000
ft2
|
Annual Production | 5,000
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $187,629 | 12,349,942 |
kWh
|
$0.015 |
Electricity Demand | $184,460 | 19,203 |
kW-mo/yr
|
$9.61 |
Natural Gas | $44,927 | 14,237 |
MMBtu
|
$3.16 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $45,580 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $38,755 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 3.1191: Change procedures / equipment / operating conditions | $2,700 | $150 | - | - | - | - |
$2,700
-
lb
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $924 | - |
$496
32,825
kWh
|
$428
-
kW-mo/yr
|
- | - | - | - | |
03 | 3.3133: Use other waste concentration methods | $1,080 | $1,530 | - | - | - |
$1,080
-
gal
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,757 | $10,246 |
$1,487
97,890
kWh
|
$1,270
-
kW-mo/yr
|
- | - | - | - | |
05 | 4.432: Cross-train personnel to avoid lost time | $26,000 | - | - | - | - | - | - | $26,000 | |
06 | 2.2442: Preheat combustion air with waste heat | $5,294 | $12,700 | - | - |
$5,294
-
MMBtu
|
- | - | - | |
07 | 4.621: Use fixtures to reduce machine changeout times | $6,825 | $50 | - | - | - | - | - | $6,825 | |
TOTAL RECOMMENDED | $45,580 | $24,676 |
$1,983
130,715
kWh
|
$1,698
-
kW-mo/yr
|
$5,294
-
MMBtu
|
$1,080
-
gal
|
$2,700
-
lb
|
$32,825 | ||
TOTAL IMPLEMENTED | $38,755 | $24,626 |
$1,983
130,715
kWh
|
$1,698
-
kW-mo/yr
|
$5,294
-
MMBtu
|
$1,080
-
gal
|
$2,700
-
lb
|
$26,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Liquid (haz) Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs