| Assessment Year | 1995 |
|---|---|
| Principal Product | Bricks |
| NAICS |
n/a
|
| SIC | 3255: Clay Refractories |
| Sales Range | $10 M to 50M |
| # of Employees | 80 |
| Plant Area |
90,000
ft2
|
| Annual Production | 73,000,000
pieces
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Oklahoma |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $341,555 | 6,848,476 |
kWh
|
$0.050 |
| Natural Gas | $628,282 | 233,907 |
MMBtu
|
$2.69 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $7,183 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $4,620 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $3,638 | $7,000 |
$3,638
125,440
kWh
|
|
| 02 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,196 | $8,775 |
$1,196
41,325
kWh
|
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $964 | $2,998 |
$964
33,118
kWh
|
|
| 04 | 2.7144: Install spectral reflectors / delamp | $1,016 | $50 |
$1,016
35,170
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $290 | $1,186 |
$290
9,965
kWh
|
|
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $61 | $171 |
$61
2,052
kWh
|
|
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18 | $20 |
$18
586
kWh
|
|
| TOTAL RECOMMENDED | $7,183 | $20,200 |
$7,183
247,656
kWh
|
||
| TOTAL IMPLEMENTED | $4,620 | $10,018 |
$4,620
159,144
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs