Assessment Year | 1995 |
---|---|
Principal Product | Ceramic tiles |
NAICS |
n/a
|
SIC | 3523: Farm Machinery and Equipment |
Sales Range | $10 M to 50M |
# of Employees | 200 |
Plant Area |
300,000
ft2
|
Annual Production | 38,000
thousand feet
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $654,373 | 14,880,715 |
kWh
|
$0.044 |
Natural Gas | $573,590 | 228,522 |
MMBtu
|
$2.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $15,939 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $15,157 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,046 | $2,349 |
$1,046
26,377
kWh
|
|
02 | 2.7135: Install occupancy sensors | $782 | $910 |
$782
26,377
kWh
|
|
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $12,563 | $32,566 |
$12,563
321,512
kWh
|
|
04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,548 | - |
$1,548
52,462
kWh
|
|
TOTAL RECOMMENDED | $15,939 | $35,825 |
$15,939
426,728
kWh
|
||
TOTAL IMPLEMENTED | $15,157 | $34,915 |
$15,157
400,351
kWh
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs